$178.182,00
10% de descuento pagando con Transferencia
Ver más detalles
Descripcion
Indice
Autores
Muestra
Ficha Técnica
Descripción

Gain confidence and expertise with stereoelectroencephalography (SEEG) as a presurgical method for epilepsy with this helpful resource. Edited and written by leading experts in the field, Stereoelectroencephalography teaches the scientific and medical bases of SEEG through its essential disciplines (anatomy, biophysics, electrophysiology, and cognitive and behavioral neuroscience) and their interrelations. It fully covers the basic and clinical aspects of the pharmaco-resistant epilepsies investigated with SEEG and their surgical indications.

  • Describes the evolution in time of the presurgical methods leading to the current practice of SEEG.

  • Explains how to determine the anatomical basis of electrode implantation, its referential system, and how it prepares rational planning to tailored resection or ablation.

  • Examines the nature of the SEEG signal, how the depth electrodes capture it, and how the dynamics of multiple cortical sites recording can be understood.

  • Contains chapters on key topics such as the optimal SEEG electrode, intracerebral electrodes implantation technique, seizure onset: interictal, preictal/ictal patterns and the epileptogenic zone, how to define the extent of the EZ by applying signal processing methods, the role of SEEG in exploring lesional epilepsy cases, and much more.

  • Presents the logical chain linking SEEG to anatomically pre-planned surgery.

  • Includes discussions of in-depth illustrative cases.

1. The Fundamentals of Stereoelectroencephalography - p. Page i 2. Cover - p. Page i 3. Front Matter - p. Page ii 4. Table of Contents - p. Page iii 5. Copyright - p. Page iv 6. Contributors - p. Page iv 7. Preface - p. Page v 8. List of Illustrations - p. Page vii 9. List of Tables - p. Page viii 10. Chapter 1 : Creation and Evolution of SEEG - p. Page viii 11. Chapter 2 : Concepts of Cortical Anatomy and Talairach Stereotaxic Space Applied to the SEEG Method - p. Page 5 12. Chapter 3 : The Stereotactic Technique in the SEEG Method - p. Page 19 13. Chapter 4 : Neural Scales in SEEG: Biophysical Principles and Technological Advances - p. Page 30 14. Chapter 5 : The SEEG Signal—Understanding Human Intracranial Electrophysiology - p. Page 44 15. Chapter 6 : What Is Seizure Onset? Interictal, Preictal/Ictal Patterns, and the Epileptogenic Zone - p. Page 63 16. Chapter 7 : The Extent of an Epileptogenic Zone: Application of Signal Processing Methods - p. Page 82 17. Chapter 8 : Anatomo-electro-clinical Correlations - p. Page 92 18. Chapter 9 : Method of Direct Cortical Stimulation for Triggering Seizures - p. Page 118 19. Chapter 10 : Electrical Stimulation for Functional Mapping During SEEG Exploration - p. Page 126 20. Chapter 11 : The Utility of Stereoelectroencephalography in Lesional Epilepsy - p. Page 147 21. Chapter 12 : From SEEG Explorations to Surgical Interventions - p. Page 162 22. Index - p. Page 176

Descripcion
Descripción

Gain confidence and expertise with stereoelectroencephalography (SEEG) as a presurgical method for epilepsy with this helpful resource. Edited and written by leading experts in the field, Stereoelectroencephalography teaches the scientific and medical bases of SEEG through its essential disciplines (anatomy, biophysics, electrophysiology, and cognitive and behavioral neuroscience) and their interrelations. It fully covers the basic and clinical aspects of the pharmaco-resistant epilepsies investigated with SEEG and their surgical indications.

  • Describes the evolution in time of the presurgical methods leading to the current practice of SEEG.

  • Explains how to determine the anatomical basis of electrode implantation, its referential system, and how it prepares rational planning to tailored resection or ablation.

  • Examines the nature of the SEEG signal, how the depth electrodes capture it, and how the dynamics of multiple cortical sites recording can be understood.

  • Contains chapters on key topics such as the optimal SEEG electrode, intracerebral electrodes implantation technique, seizure onset: interictal, preictal/ictal patterns and the epileptogenic zone, how to define the extent of the EZ by applying signal processing methods, the role of SEEG in exploring lesional epilepsy cases, and much more.

  • Presents the logical chain linking SEEG to anatomically pre-planned surgery.

  • Includes discussions of in-depth illustrative cases.

1. The Fundamentals of Stereoelectroencephalography - p. Page i 2. Cover - p. Page i 3. Front Matter - p. Page ii 4. Table of Contents - p. Page iii 5. Copyright - p. Page iv 6. Contributors - p. Page iv 7. Preface - p. Page v 8. List of Illustrations - p. Page vii 9. List of Tables - p. Page viii 10. Chapter 1 : Creation and Evolution of SEEG - p. Page viii 11. Chapter 2 : Concepts of Cortical Anatomy and Talairach Stereotaxic Space Applied to the SEEG Method - p. Page 5 12. Chapter 3 : The Stereotactic Technique in the SEEG Method - p. Page 19 13. Chapter 4 : Neural Scales in SEEG: Biophysical Principles and Technological Advances - p. Page 30 14. Chapter 5 : The SEEG Signal—Understanding Human Intracranial Electrophysiology - p. Page 44 15. Chapter 6 : What Is Seizure Onset? Interictal, Preictal/Ictal Patterns, and the Epileptogenic Zone - p. Page 63 16. Chapter 7 : The Extent of an Epileptogenic Zone: Application of Signal Processing Methods - p. Page 82 17. Chapter 8 : Anatomo-electro-clinical Correlations - p. Page 92 18. Chapter 9 : Method of Direct Cortical Stimulation for Triggering Seizures - p. Page 118 19. Chapter 10 : Electrical Stimulation for Functional Mapping During SEEG Exploration - p. Page 126 20. Chapter 11 : The Utility of Stereoelectroencephalography in Lesional Epilepsy - p. Page 147 21. Chapter 12 : From SEEG Explorations to Surgical Interventions - p. Page 162 22. Index - p. Page 176

Indice
Autores
Muestra
Ficha Técnica